A Safer Approach to Verifying the Absence of Voltage
Best Practices to Prevent Electrical Injuries and Fatalities in Industrial Facilities
Protecting workers around electrical equipment isn’t optional—it’s a core responsibility. Yet despite decades of safety campaigns and evolving standards, electrical-related injuries and fatalities remain stubbornly high. The question is: Why?
The Persistent Risk of Electrical Incidents
Most electrical accidents happen because someone believed equipment was de-energized when it wasn’t—or they knowingly worked near energized parts without proper precautions or training.
According to the Electrical Safety Foundation International (ESFI), nearly half of all reported workplace fatalities from 2011 to 2022 occurred while working with or near live electrical parts. Even more troubling, these incidents involve not only inexperienced staff but also seasoned workers with years on the job. Data from the Survey of Occupational Injury and Illness (SOII) shows a majority of nonfatal electrical injuries happen to workers with more than a year of experience.
The takeaway is clear: human error remains a leading cause of electrical incidents, regardless of experience.

How Voltage Testing Has Evolved
Multimeters – The Traditional Method
Historically, verifying the absence of voltage meant opening a cabinet, wearing full PPE, and using a multimeter to test phase conductors directly. While this method is widely accepted, it introduces opportunities for mistakes—like incorrect equipment use, loose probes, or accidental contact with live parts.
From 2015–2017, despite widespread use of multimeters, there was no meaningful decline in electrical injuries or fatalities. That stagnation triggered a search for safer alternatives.
Voltage Test Ports – A Step Forward
In 2018, NFPA 70E introduced an exception that allowed permanently mounted voltage test devices to verify absence of voltage. Test ports became common, allowing workers to test voltage with the cabinet door closed—reducing contact risk.
But while these devices added a layer of safety, they didn’t significantly lower incident rates. Why?
- A test port may read 0V even when voltage is present—for example, if there’s a blown fuse or faulty wiring between the test port and the conductors.
- Lack of trust in the reading may lead qualified workers to open the door anyway, defeating the purpose of the system.
Despite their limitations, voltage test ports remain a recognized safety tool. NFPA 70E’s 2024 edition now includes them in Annex O.2.4 as part of a “Safety-by-Design” approach.
The Rise of Absence of Voltage Testers (AVTs)
AVTs offer a next-level solution. Unlike test ports or handheld meters, AVTs are permanently mounted, automated systems that confirm absence of voltage without opening the equipment.
NFPA 70E first formally recognized AVTs in its 2021 update, replacing “permanently mounted test device” with “permanently mounted absence of voltage tester.” These devices must comply with UL 1436 standards, and more recently, the 2024 NFPA 70E update emphasizes that testing must occur “at each point of work.”
How AVTs Work
Using an AVT is simple and safe:
- With the press of a button, a test sequence initiates.
- The system performs a continuity check to ensure secure wiring.
- It then verifies absence of both AC and DC voltage—phase-to-ground and phase-to-phase.
- The process repeats for validation.
- If voltage is below 3V, green lights signal it’s safe to open the panel.
- If unsafe, amber lights stay on, prompting a retest or escalation with PPE.
This process removes the guesswork and physical risk that comes with traditional testing methods.

Why AVTs Are a Game-Changer
- Minimized Human Error: Automation ensures consistency and eliminates manual missteps.
- Zero Exposure Testing: Voltage is verified with the door closed—eliminating unnecessary risk.
- Clear Visual Feedback: Workers can immediately see if it’s safe to proceed.
- High Reliability: AVTs follow Functional Safety IEC 61508 and carry SIL 3 certification, meaning failure is statistically less than once in over 1,000 years of continuous operation.
AVTs are mounted on the load side of the disconnect and are completely isolated from live voltage on the door side. The display connects via communication cable, ensuring no dangerous current reaches the user interface.
Building Trust, Building Safety Culture
A reliable AVT does more than reduce risk—it builds confidence. When workers trust their tools, they’re less likely to bypass procedures or take shortcuts. Over time, this fosters a stronger safety culture—one where procedures are followed because they’re proven effective, not just required by policy.
Conclusion: Rethinking Voltage Verification
AVTs represent a safer, smarter way to verify the absence of voltage. They reduce the need for PPE-intensive manual testing, limit exposure to electrical hazards, and help prevent the kinds of tragic incidents that still occur far too often.
Electrical safety isn’t just about compliance—it’s about culture, tools, and trust.
Is your facility using the best available methods to protect your team?
If not, it’s time to take a serious look at AVTs. At Diamond Bar Electric, we can help you integrate AVTs and other smart safety solutions that align with current NFPA standards and your facility’s needs. Contact us today to learn more.